Item # 350/3RJG, Round Double Jacketed Submersible Pump Cable

Item # 350/3RJG, Round Double Jacketed Submersible Pump Cable

Available Options:

Length:
Notes:

Voltage Rating600 Volts
Conductor Size350 MCM
Cable O.D1.983 in
Temperature Rating75 °C
InsulationHIGH DIELECTRIC POLYVINYL CHLORIDEUL-83 TABLE 13.1(thwn 75 C)UL-83 TABLE 14.1(THHN 90 C)THICKNESS UL-83 TABLE 21.5
Color CodeBlack Insulation with ICEA method 4 printed number code.
Number of Conductors4
Weight per M Ft.4315 lbs
JacketWith Overall Jacket
LocationsDry Wet
Number of Conductor Strands37
Conductor Strand O.D0.0973 in
Conductor O.D0.809 in
PVC Jacket Thickness(Conductor)0.060 in
Nylon Jacket Thickness(conductor)0.008 in
Ground wire Size3 AWG
Number of Strands-Ground Wire7
Strand O.D - Ground Wire0.0867 in
ConductorsBare, Soft annealed copper per ASTM B-3 SIZES 8 THROUGH 2 AWG Concentric stranded, Class B (7 Strands) ASTM B-8 and UL-83 table 4.1Sizes 250 THROUGH 500MCM Concentric Stranded. Class B(37 Strands) ASTM B-* and UL-83 table 4.1
Insulation ArmorNYLON UL-83 paragraph 35.1THICKNESS UL-83 table 21.5
Cable AssemblySIZES 8 THROUGH 4/0 AWGThree or more conductors are assembled Round with fillers as needed. A tape binder IS applied over the assembly. Two Conductors are assembled Flat parallel (round, with fillers as needed, is available upon request.)SIZES 350 THROUGH 500 MCMConductors are assembled round with fillers as needed. A tape binder is applied over the assembly
Overall JacketPoly Vinyl chloride UL-62 part 22 class 12 Thickness specified herein
MarkingsInk Printed on jacket (size) AWG or submersible pump cable.THHN or THWN cdrs. sunlight resistant 600v(UL) Direct Burial.Indent print on the other side of jacket (number of conductors)
Construction OptionsConsult factory for cable specifications with Ground
TestThis specification covers Two, three and four Conductor cables having Vw-1 THHN/THWN (PVC Nylon) conductors With an overall polyvinyl chloride(PVC)jacket, conforming to article 318 and article 340 " Power and Control Cable of 1981 National Electrical code, and Subject 1277 of Underwriters Laboratories, Inc meets the requirements of the 70,000 BTU Test per IEEE-383 and shows reserve capablilities by also Passing the 210,000 BTU Flame test. Rate 600 Volts, 90 C dry and 75 C wet.
UseUL Listed and OSHA acceptable. Recognized for use in Class 1, Division 2 Hazardous locations and for installation in trays. Wireways, troughs, Channels, ducts, and conduit.Specifically approved for direct burial, wet or dry locations and sunlight resistan

TestThis specification covers Two, three and four Conductor cables having Vw-1 THHN/THWN (PVC Nylon) conductors With an overall polyvinyl chloride(PVC)jacket, conforming to article 318 and article 340 " Power and Control Cable of 1981 National Electrical code, and Subject 1277 of Underwriters Laboratories, Inc meets the requirements of the 70,000 BTU Test per IEEE-383 and shows reserve capablilities by also Passing the 210,000 BTU Flame test. Rate 600 Volts, 90 C dry and 75 C wet.
UseUL Listed and OSHA acceptable. Recognized for use in Class 1, Division 2 Hazardous locations and for installation in trays. Wireways, troughs, Channels, ducts, and conduit.Specifically approved for direct burial, wet or dry locations and sunlight resistan
InsulationHIGH DIELECTRIC POLYVINYL CHLORIDEUL-83 TABLE 13.1(thwn 75 C)UL-83 TABLE 14.1(THHN 90 C)THICKNESS UL-83 TABLE 21.5
Color CodeBlack Insulation with ICEA method 4 printed number code.